Maxim-integrated 73M1866B/73M1966B Reference Driver Manual do Utilizador Página 63

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 98
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 62
UG_1x66B_015 73M1866B/73M1966B Reference Driver User Guide
Rev. 2.7 63
The following example code illustrates a reading of a line voltage IET table entry.
M1966_MEASURE_UPDATE_t read;
int ret;
read.row = 5; /* read row 5 of voltage IET table */
read.action = M1966_MEASURE_ACTION_GET; /* request for GET operation */
read.entity = M1966_MEASURE_ENTITY_VOLTAGE; /* measuring entity= voltage */
ret = ioctl (fd, M1966_MEASURE_UPDATE, &read);
if (ret < 0)
printf (“Failed to read voltage IET entry”);
else {
printf (“\nReading voltage IET table entry row: %d, read.row);
printf (“\nInterval min: %d”, read.interval_min);
printf (“\nInterval max: %d”, read.interval_max);
printf (“\nEvent : 0x%08X”, read.event);
}