78M6610+LMU Evaluation Kit User Manual
Rev 1 21
6.1.1 Jumper Position Changes
Move J23 and J24 jumpers to position CT to use CT2 and remove jumper at J9.
J23 Jumper Description
1/2 Connect J15 SHUNT to 78M6610+LMU Sensor Slot 1 Installed
2/3 Connect J10 CT2+ to 78M6610+LMU Sensor Slot 1 -
J24 Jumper Description
J24 Pins Description Jumper
1/2 Connects J8 SHUNT to 78M6610+LMU Sensor Slot 1 Installed
2/3 Connects J10 CT2- to 78M6610+LMU Sensor Slot 1 -
J9 Jumper Description
1/2 Connect AC Neutral to V3P3A (chip reference) Installed
6.1.2 Device Configuration
Use the Configuration tab to map the sensors as shown in the table below. Re-enter the gain value for CT2
(located on bottom of board) into the S1_GAIN register if needed.
Note: The values for VC and IB will not be displayed correctly on the Power tab of the provided GUI due to the
increased full-scale values of VC and IB. Reported results for measurements derived from VC and IB will be
one-half the expected magnitude.