12.1.3 Capture Mode
The Timer B 16-bit capture mode is configured by setting the CP/RLB bit to 1. A block diagram of this mode is shown
in Figure 12-3. In capture mode, the Timer B can be clocked either by a prescaled version of the system clock or fall-
ing edges of the TBA pin. When the timer is enabled in capture mode, it begins counting up from the value contained
in the TB0V register until reaching an overflow state. An overflow state is when the TB0V register changes from FFFFh
to 0000h. When this happens, the timer overflow flag (TFB), is set, which can generate an interrupt if enabled. After an
overflow the timer continues counting upward. This counting is repeated without processor intervention until the timer
is disabled (TRB = 0).
The current value in TB0V is captured and copied into the capture/reload register (TB0R) when a falling edge occurs on
the TBB pin and the external enable bit (EXENB) of the control register is set to 1. The EXFB flag is set when a capture
occurs, which can generate an interrupt if enabled. If the EXENB bit is cleared to 0, transitions on the TBB pin do not
cause a capture event.
Figure 12-3. Capture Mode Block Diagram
SYSTEM
CLOCK
CLOCK PRESCALER
TBPS[2:0]
FALLING
EDGE
EXFB = 1
CLK
15 0
TB0V
TB0R
TFB = 1
15 0
CAPTURE
TBA PIN
TRB
TBB PIN
EXENB
0
1
C/TB
ETB
TIMER B
INTERRUPT