Maxim Integrated 3-7
MAX31782 User’s Guide
Revision 0; 8/11
3.1.7 Interrupt Identification Register (IIR, 8h[Bh])
Initialization: This register is cleared to 00h on all forms of reset.
Access: Read-only.
3.1.8 System Clock Control Register (CKCN, 8h[Eh])
Initialization: This register is cleared to 10h on all forms of reset.
Access: Unrestricted read/write access.
The first six bits in this register indicate interrupts pending in modules 0 to 5, one bit per module. The eighth bit, IIS, indicates a
pending system interrupt, such as from the watchdog timer. The interrupt pending flags are set only for enabled interrupt sources
waiting for service. The interrupt pending flag is cleared when the pending interrupt sources within that module are disabled or
when the interrupt flags are cleared by software.
BIT FUNCTION
IIR.0 (II0) Interrupt Identifier Flag for Register Module 0
IIR.1 (II1) Interrupt Identifier Flag for Register Module 1
IIR.2 (II2) Interrupt Identifier Flag for Register Module 2
IIR.3 (II3) Interrupt Identifier Flag for Register Module 3
IIR.4 (II4) Interrupt Identifier Flag for Register Module 4
IIR.5 (II5) Interrupt Identifier Flag for Register Module 5
IIR.6 Reserved. Reads return 0.
IIR.7 (IIS) Interrupt Identifier Flag for System Modules
BIT FUNCTION
CKCN.[3:0] Reserved. All reads return 0.
CKCN.4 (STOP)
Stop Mode Select. Setting this bit to 1 stops program execution and commences low-power operation. This
bit is cleared by a reset or any of the enabled external interrupts. Setting and resetting the STOP bit does not
change the system clock source and its divide ratio.
CKCN.[6:5] Reserved. All reads return 0.
CKCN.7 Reserved. All reads return 1.