12.4.8 Endpoint Stall Register (EPSTL)
Bit 7: Reserved. Reads returns zero.
Bit 6: Acknowledge Status Stage (ACKSTAT). When this bit is set to 1, the SIE responds to the host with an ACK
handshake in the status stage of control transfer. Until the CPU either acknowledges (ACKSTAT = 1) or stalls the trans-
fer, the SIE answers the status stage of the control transfer with the NAK handshake. This bit is cleared after the SIE
sends an ACK handshake in the status stage of a control transfer, new setup packet has been detected, or the stall
bit(s) is set. This bit can also be cleared by CPU writing a 0.
Bit 5: Stall Status Stage (STLSTAT). The stall status stage bit, together with the ACKSTAT bit, indicates to the SIE how
to respond in the status stage of a control transfer. When this bit is cleared to 0, the ACKSTAT bit controls the status
stage of a control transfer. When this bit is set to 1, the SIE always sends a stall response to the host in response to
a control transfer. Until the CPU either acknowledges (ACKSTAT = 1) or stalls the transfer, the SIE answers the status
stage of a control transfer with the NAK handshake. This bit remains set unless cleared by software. This bit is auto-
matically cleared upon the arrival of a setup token.
Bit 4: EP3-IN Stall (STLEP3). If set to 1, the SIE returns a stall handshake for an IN request directed to EP3 regardless
of the status of the other control bits. This bit remains set unless cleared by software.
Bit 3: EP2-IN Stall (STLEP2). If set to 1, the SIE returns a stall handshake for an IN request directed to EP2 regardless
of the status of the other control bits. This bit remains set unless cleared by software.
Bit 2: EP1-OUT Stall (STLEP1). If set to 1, the SIE returns a stall handshake for an OUT request directed to EP1
regardless of the status of the other control bits. This bit remains set unless cleared by software.
Bit 1: EP0-OUT Stall (STLOUT0). If set to 1, the SIE returns a stall handshake for an OUT request directed to EP0
regardless of the status of the other control bits. This bit remains set unless cleared by software. This bit is automati-
cally cleared upon the arrival of a setup token.
Bit 0: EP0-IN Stall (STLIN0). If set to 1, the SIE returns a stall handshake for an IN request directed to EP0 regardless
of the status of the other control bits. This bit remains set unless cleared by software. This bit is automatically cleared
upon the arrival of a setup token.
Register Name
EPSTL
Register Description
Endpoint Stall Register
Register Address
UADDR[4:0] = 08h
Bit # 7 6 5 4 3 2 1 0
Name — ACKSTAT STLSTAT STLEP3 STLEP2 STLEP1 STLOUT0 STLIN0
Reset 0 0 0 0 0 0 0 0