MAXQ612/MAXQ622 User’s Guide
16-12 Maxim Integrated
Data Transfer Rules
dst (16-bit) ← src (16-bit): dst[15:0] ← src[15:0]
dst (8-bit) ← src (8-bit): dst[7:0] ← src[7:0]
dst (16-bit) ← src (8-bit): dst[15:8] ← 00h *
dst[ 7:0] ← src[7:0]
dst (8-bit) ← src (16-bit): dst[7:0] ← src[7:0]
* Note: The PFX[0] register may be used to supply a separate high order data byte for this type of
transfer.
Example(s):
MOVE A[0], A[3]
; A[0] ← A[3]
MOVE DP[0], #110h
; DP[0] ← #0110h (PFX[0] register used)
; MOVE PFX[0], #01h (smart-prefixing)
; MOVE DP[0], #10h
MOVE DP[0], #80h
; DP[0] ← #0080h (PFX[0] register not needed)
Special
Notes:
Proper loading of the PFX[n] registers, when for the purpose of supplying 16-bit immediate data
or accessing 2-cycle destinations, is handled automatically by the assembler and is therefore an
optional step for the user when writing assembly source code. Examples of the automatic PFX[n]
code insertion by the assembler are demonstrated below.
Initial Assembly Code Assembler Output
MOVE DP[0], #0100h MOVE PFX[0], #01h
MOVE DP[0], #00h
MOVE A[15], A[7] MOVE PFX[2], anysrc
MOVE A[7], A[7]
MOVE A[8], #3040h MOVE PFX[2], #30h
MOVE A[0], #40h
MOVE Acc.<b>, C Move Carry Flag to Accumulator Bit
Description:
Replaces the specified bit of the active accumulator with the Carry bit.
Status Flags:
S, Z
Operation:
Acc.<b> ← C
Encoding:
15
0
1111 1010 bbbb 1010
Example(s):
; Acc = 8000h, S=1, Z=0, C=0
MOVE Acc.15, C ; Acc = 0000h, S=0, Z=1
MOVE C, Acc.<b> Move Accumulator Bit to Carry Flag
Description:
Replaces the Carry (C) status flag with the specified active accumulator bit.
Status Flag:
C
Operation:
C ← Acc.<b>
Encoding:
15
0
1110 1010 bbbb 1010
Example(s):
; Acc = 01C0h, C=0
MOVE C, Acc.8 ; C =1