19-21 _________________________________________________________________________________________________________
MAXQ7667 Users Guide
RET Return from Subroutine
Description:
RET pops a single word from the stack (@SP) into the Instruction Pointer (IP) and decrements the stack pointer (SP).
The decremented SP is saved as the new stack pointer (SP).
Status Flags: None
Operation: IP @ SP--
Encoding: 15 0
Example(s): RET
Code Execution:
Stack Data:
SP (before RET)
SP (after RET)
RET C/RET NC, RET Z/RET NZ, RET S Conditional Return on Status Flag
Description: Performs conditional return (RET) based upon the state of a specific processor status flag. RET C returns if the Carry
flag is set while RET NC returns if the Carry flag is clear. RET Z returns if the Zero flag is set while RET NZ returns if
the Zero flag is clear. RET S returns if the Sign flag is set. See RET for additional information on the return operation.
Status Flags: None
RET C C=1: IP @SP--
Operation: C=0: IP IP + 1
Encoding: 15 0
Example(s): RET C ; C=1, return (RET) is performed
1010
1100
0000
1101
1000
1100
0000
1101
Addr (IP)
Op Code
0311h • • •
0312h RET
0103h • • •
xxxxh
xxxxh
0103h
xxxxh
xxxxh